Staubli 32.0081-UR MC4 Cable Connector w/Boot 6.05–8.56mm Male PV-KST4/8II-UR
Stellavolta.com is an authorized dealer and we only sell new products. Review this product’s handling time by clicking on the “Shipping and Payments” tab above. Ships primarily via USPS, however, we may ship UPS Ground or FedEx Ground. Faster shipping options available. We accept PayPal and all major credit cards. Staubli 32.0081-UR MC4 Cable Coupler with Barrel Crimp Contacts for 8 AWG 6.05 – 8.56 mm PV Wire, Male, PV-KST4/8II-UR Snap-in locking Locking by safety lock clip PV-KST4/8II-UR in accordance with NEC 2011, can be released only with tool Proven MC-Multilam technology with high long-term stability Tried and tested plug connectors Exchanges or Returns Please contact us before returning or exchanging an item to receive a return authorization (RA). Items returned to us without receiving a return authorization will be returned to you at your expense. We accept exchanges and returns for unopened items or damaged/defective products within 30 days of receipt of shipment. A 20% restocking fee may apply to multiple quantity returns or large ticket items. A 20% restocking fee will apply for all products that ship freight. Exchanges and returns are not accepted after 30 days of receipt of shipment. Unopened Products To make an exchange or return for an unopened product, please contact us and obtain a Return Authorization. If the exchanged or returned product is unopened with all original accessories, manuals, packaging, and/or shrink wrap, you will be responsible for return shipping. If the product was sold with free shipping, shipping charges to deliver the item will be deducted from the refund amount. A refund to your method of payment will be processed within one week of receiving an authorized return minus any applicable shipping charges. Damaged/Defective Products To make an exchange or return for a damaged/defective product, please contact us and obtain a Return Authorization. If the product is returned for being damaged/defective, we will provide a return shipping label for domestic shipping costs. If we test and confirm the product is damaged/defective and receive the product along with all original accessories, manuals, and packing, we will provide a refund for the purchase price of the product, plus domestic shipping charges, if any, assessed at the time of purchase. International shipping charges, if any, will not be reimbursed. A refund to your method of payment will be processed within one week of receiving an authorized return. If we test and confirm the product is in full working order, a refund will not be provided and you will be responsible for providing a return shipping label to have the product returned to you.
LOT 1000V 30A MALE & FEMALE WIRE CABLE CONNECTOR ADAPTER SET FOR MC4 SOLAR PANEL
Lot 1-100 Pairs for Connectors Solar Panel 30A Line Plug Socket Male Female IP67. Rated Current: 30A. Resistance of extra high & low temperature and fireproof. Each pair is as shown in the pictures. Our staff is happy to assist you in any way possible.
5 SETS 6MM MULTI-CONTACT MC4 BRAND PV CABLE CONNECTOR FOR SOLAR PANEL
5 SETS 6MM MULTI-CONTACT MC4 PV CABLE CONNECTOR FOR SOLAR PANEL 5 Sets of 6MM Multi-Contact MC4 PV Solar Cable Connectors Read below on the deal on why all of these connectors are not created equal Features:Brand new top qualityQuick easy assemblyHot and cold temperature resistanceSeal for waterproofingTin plated copper contacts Male/Female Connector Specifications: Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG & #10 AWG PV Wire. This male connector has a negative polarity (-).Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG #10AWG PV Wire. This female connector has a positive (+) polarity.Snap-in lockingLocking by safety lock clip PV-SSH4 in accordance with NEC 2011, can be released only with toolFor use on # 12AWG & #10AWG pv rated wire.Rated Voltage = 2000V DC (IEC) & 1000V DC (UL).Rated current IEC (90 Degrees C) = 30A (4mm, 6mm, 10 AWG).Test voltage = 6kV (50Hz, 1min.)Ambient temperature range = -40 C…+90 C (IEC) & -40 C…+ 75 C.Upper limiting temperature = 105 Degrees C (IEC)Overvoltage category / Pollution degree = CATIII / 3Contact resistance of plug connectors = 0,35mOSafety class = IIFlame class = UL94-V0Ammonia resistance = 1500h, 70 C / 70% RH, 750ppmSalt mist spray test degree of severity 6 = EC 60068-2-52 Fact is some of the connectors for sale on outlets such as eBay, Amazon and the internet in general are simply recycled plastic which allows connections to corrode in what we are seeing as little as 18 months. As a price point we understand the need to be as economical as possible however cheap does not necessarily mean value. See the report below written on the use of generic connectors labeled as MC4. Advanced Contact Technology General statement by Multi-Contact on mating connectors of different make Multi-Contact clearly dissociates itself from connections made with MC connectors and connectors from other manufacturers due to the high demands placed on safety and reliability of PV installations. Connectors that have not been produced by MC but appear mate-able with MC components,and sometimes are being advertised as “compatible with MC” by the manufacturers do not meet the requirements for safe, stable electrical connections and must not be mated with MC connectors for safety reasons. Multi-Contact does not take any responsibility for damages that result from such connections which have not been approved by MC. Loss of certification The MC4 connectors made by Multi-Contact are TÜV certified only in combination with connectors from the MC4 product range. Any other connections are not TÜV recognized. When other manufacturers advertise a TÜV certified connection of their connectors with MC products, this does not refer to the connection as such. Only partial tests have been made in such cases.Technical risks and long-term performance No long-term experience is available with cross-mating from the field. Experts question the forecast capability of short-term tests and accelerated aging tests with regard to the quality of a connection over a time span of 25 years or more. PV connectors are safety components which contribute to the operational safety (both personal and functional) of the installation. When connectors of different make are mated, this aspect is not guaranteed. Contact elements and insulation elements must be perfectly matched to the last detail. Over along period of time this may only be ensured by continuous in-process tests which are run in- house by the manufacturer. Multi-Contact has been on the market with PV connector systems for over 15 years, looking back on according experience from both research and development as well as long-term performance of missions of connections. Simultaneously, characteristics of the connections are being recorded in test fields, proving a good long-term behaviour. For cross-mated connections this certainty is no longer given Hurricane Wind Power 2019Corporate America Today2019 Best Off-Grid Renewable Energy Product Supplier – USAUP TO 50% DISCOUNTSTOP BRANDSPaymentShippingReturnsPaymentShippingReturns We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement. If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. See our other itemsThank you for visiting our Ebay store!5 Sets of 6MM Multi-Contact MC4 PV Solar Cable Connectors Read below on the deal on why all of these connectors are not created equal Features: —Brand new top quality —Quick easy assembly —Hot and cold temperature resistance —Seal for waterproofing —Tin plated copper contacts Male/Female Connector Specifications: Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG & #10 AWG PV Wire. This male connector has a negative polarity (-). Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG #10AWG PV Wire. This female connector has a positive (+) polarity. Snap-in locking Locking by safety lock clip PV-SSH4 in accordance with NEC 2011, can be released only with tool For use on # 12AWG & #10AWG pv rated wire. Rated Voltage = 2000V DC (IEC) & 1000V DC (UL). Rated current IEC (90 Degrees C) = 30A (4mm, 6mm, 10 AWG). Test voltage = 6kV (50Hz, 1min.) Ambient temperature range = -40 C…+90 C (IEC) & -40 C…+ 75 C. Upper limiting temperature = 105 Degrees C (IEC) Overvoltage category / Pollution degree = CATIII / 3 Contact resistance of plug connectors = 0,35mO Safety class = II Flame class = UL94-V0 Ammonia resistance = 1500h, 70 C / 70% RH, 750ppm Salt mist spray test degree of severity 6 = EC 60068-2-52 Fact is some of the connectors for sale on outlets such as eBay, Amazon and the internet in general are simply recycled plastic which allows connections to corrode in what we are seeing as little as 18 months. As a price point we understand the need to be as economical as possible however cheap does not necessarily mean value. See the report below written on the use of generic connectors labeled as MC4 Advanced Contact Technology General statement by Multi-Contact on mating connectors of different make Multi-Contact clearly dissociates itself from connections made with MC connectors and connectors from other manufacturers due to the high demands placed on safety and reliability of PV installations. Connectors that have not been produced by MC but appear mateable with MC components,and sometimes are being advertised as “compatible with MC” by the manufacturers do not meet the requirements for safe, stable electrical connections and must not be mated with MC connectors for safety reasons. Multi-Contact does not take any responsibility for damages that result from such connections which have not been approved by MC. Loss of certification The MC4 connectors made by Multi-Contact are TÜV certified only in combination with connectors from the MC4 product range. Any other connections are not TÜV recognized. When other manufacturers advertise a TÜV certified connection of their connectors with MC products, this does not refer to the connection as such. Only partial tests have been made in such cases.Technical risks and long-term performance No long-term experience is available with cross-mating from the field. Experts question the forecast capability of short-term tests and accelerated aging tests with regard to the quality of a connection over a time span of 25 years or more. PV connectors are safety components which contribute to the operational safety (both personal and functional) of the installation. When connectors of different make are mated, this aspect is not guaranteed. Contact elements and insulation elements must be perfectly matched to the last detail. Over along period of time this may only be ensured by continuous in-process tests which are run in- house by the manufacturer. Multi-Contact has been on the market with PV connector systems for over 15 years, looking back on according experience from both research and development as well as long-term performance of missions of connections. Simultaneously, characteristics of the connections are being recorded in test fields, proving a good long-term behaviour. For cross-mated connections this certainty is no longer given [ ] (http://msm-newage-clicks-v1.onpagepromotions.com/v1/clicks/taglines/cdf4b8a4bada7ecf57cfffc852201997040101/2d4754dcd19cee3c8d60abefd509a8af040101/1000) Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application 5 SETS 6MM MULTI-CONTACT MC4 PV CABLE CONNECTOR FOR SOLAR PANEL 5 Sets of 6MM Multi-Contact MC4 PV Solar Cable ConnectorsRead below on the deal on why all of these connectors are not created equalFeatures:Brand new top qualityQuick easy assemblyHot and cold temperature resistanceSeal for waterproofingTin plated copper contactsMale/Female Connector Specifications: Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG & #10 AWG PV Wire. This male connector has a negative polarity (-).Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG #10AWG PV Wire. This female connector has a positive (+) polarity. Snap-in locking Locking by safety lock clip PV-SSH4 in accordance with NEC 2011, can be released only with tool For use on # 12AWG & #10AWG pv rated wire. Rated Voltage = 2000V DC (IEC) & 1000V DC (UL). Rated current IEC (90 Degrees C) = 30A (4mm, 6mm, 10 AWG). Test voltage = 6kV (50Hz, 1min.) Ambient temperature range = -40 C…+90 C (IEC) & -40 C…+ 75 C. Upper limiting temperature = 105 Degrees C (IEC) Overvoltage category / Pollution degree = CATIII / 3 Contact resistance of plug connectors = 0,35mO Safety class = II Flame class = UL94-V0 Ammonia resistance = 1500h, 70 C / 70% RH, 750ppm Salt mist spray test degree of severity 6 = EC 60068-2-52Fact is some of the connectors for sale on outlets such as eBay, Amazon and the internet in general are simply recycled plastic which allows connections to corrode in what we are seeing as little as 18 months. As a price point we understand the need to be as economical as possible however cheap does not necessarily mean value. See the report below written on the use of generic connectors labeled as MC4 Advanced Contact Technology General statement by Multi-Contact on mating connectors of different make Multi-Contact clearly dissociates itself from connections made with MC connectors and connectors from other manufacturers due to the high demands placed on safety and reliability of PV installations. Connectors that have not been produced by MC but appear mateable with MC components,and sometimes are being advertised as “compatible with MC” by the manufacturers do not meet the requirements for safe, stable electrical connections and must not be mated with MC connectors for safety reasons. Multi-Contact does not take any responsibility for damages that result from such connections which have not been approved by MC. Loss of certification The MC4 connectors made by Multi-Contact are TÜV certified only in combination with connectors from the MC4 product range. Any other connections are not TÜV recognized. When other manufacturers advertise a TÜV certified connection of their connectors with MC products, this does not refer to the connection as such. Only partial tests have been made in such cases.Technical risks and long-term performance No long-term experience is available with cross-mating from the field. Experts question the forecast capability of short-term tests and accelerated aging tests with regard to the quality of a connection over a time span of 25 years or more. PV connectors are safety components which contribute to the operational safety (both personal and functional) of the installation. When connectors of different make are mated, this aspect is not guaranteed. Contact elements and insulation elements must be perfectly matched to the last detail. Over along period of time this may only be ensured by continuous in-process tests which are run in- house by the manufacturer. Multi-Contact has been on the market with PV connector systems for over 15 years, looking back on according experience from both research and development as well as long-term performance of missions of connections. Simultaneously, characteristics of the connections are being recorded in test fields, proving a good long-term behaviour. For cross-mated connections this certainty is no longer given Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application Hurricane Wind Power 2019Corporate America Today2019 Best Off-Grid Renewable Energy Product Supplier – USAUP TO 50% DISCOUNTSTOP BRANDSSee our other itemsPayment We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! Shipping We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.Returns If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. Thank you for visiting our Ebay store! 5 Sets of 6MM Multi-Contact MC4 PV Solar Cable ConnectorsRead below on the deal on why all of these connectors are not created equalFeatures:Brand new top qualityQuick easy assemblyHot and cold temperature resistanceSeal for waterproofingTin plated copper contactsMale/Female Connector Specifications: Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG & #10 AWG PV Wire. This male connector has a negative polarity (-).Multi-Contact MC4 Connector with Boot for 6-9mm OD #12AWG #10AWG PV Wire. This female connector has a positive (+) polarity. Snap-in locking Locking by safety lock clip PV-SSH4 in accordance with NEC 2011, can be released only with tool For use on # 12AWG & #10AWG pv rated wire. Rated Voltage = 2000V DC (IEC) & 1000V DC (UL). Rated current IEC (90 Degrees C) = 30A (4mm, 6mm, 10 AWG). Test voltage = 6kV (50Hz, 1min.) Ambient temperature range = -40 C…+90 C (IEC) & -40 C…+ 75 C. Upper limiting temperature = 105 Degrees C (IEC) Overvoltage category / Pollution degree = CATIII / 3 Contact resistance of plug connectors = 0,35mO Safety class = II Flame class = UL94-V0 Ammonia resistance = 1500h, 70 C / 70% RH, 750ppm Salt mist spray test degree of severity 6 = EC 60068-2-52Fact is some of the connectors for sale on outlets such as eBay, Amazon and the internet in general are simply recycled plastic which allows connections to corrode in what we are seeing as little as 18 months. As a price point we understand the need to be as economical as possible however cheap does not necessarily mean value. See the report below written on the use of generic connectors labeled as MC4 Advanced Contact Technology General statement by Multi-Contact on mating connectors of different make Multi-Contact clearly dissociates itself from connections made with MC connectors and connectors from other manufacturers due to the high demands placed on safety and reliability of PV installations. Connectors that have not been produced by MC but appear mateable with MC components,and sometimes are being advertised as “compatible with MC” by the manufacturers do not meet the requirements for safe, stable electrical connections and must not be mated with MC connectors for safety reasons. Multi-Contact does not take any responsibility for damages that result from such connections which have not been approved by MC. Loss of certification The MC4 connectors made by Multi-Contact are TÜV certified only in combination with connectors from the MC4 product range. Any other connections are not TÜV recognized. When other manufacturers advertise a TÜV certified connection of their connectors with MC products, this does not refer to the connection as such. Only partial tests have been made in such cases.Technical risks and long-term performance No long-term experience is available with cross-mating from the field. Experts question the forecast capability of short-term tests and accelerated aging tests with regard to the quality of a connection over a time span of 25 years or more. PV connectors are safety components which contribute to the operational safety (both personal and functional) of the installation. When connectors of different make are mated, this aspect is not guaranteed. Contact elements and insulation elements must be perfectly matched to the last detail. Over along period of time this may only be ensured by continuous in-process tests which are run in- house by the manufacturer. Multi-Contact has been on the market with PV connector systems for over 15 years, looking back on according experience from both research and development as well as long-term performance of missions of connections. Simultaneously, characteristics of the connections are being recorded in test fields, proving a good long-term behaviour. For cross-mated connections this certainty is no longer given Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application
10 Pairs Solar Panel Cable Connectors Male/Female Compatible with MC4 Connector
Staubli MC4 PV Solar Panel Cable Connector 10 Pairs – Made in USA 10-12 AWG NEW
Staubli MC4 PV Solar Panel Cable Connector 10 Pairs – Made in USA 10-12 AWG
10-100Set Male Female Wire Cable Connector Set Solar Panel Waterproof Connector
Resistance of extra high & low temperature and fireproof. Connecting system: crimping connection. Withdrawal force: ≥50N. Insertion force: ≤50N. Suitable cable: 2.5mm2, 4mm2, 6mm2 (AWG14, AWG12, AWG10).
10/20/50/100/200 Pairs Solar Cable Connectors Male Female Waterproof Solar Panel
10/20/50/100/200 Pairs solar connectors. Resistance of extra high & low temperature and fireproof. Suitable cable: 2.5mm2, 4mm2, 6mm2 (AWG14, AWG12, AWG10). Rated Current: 22(2.5 mm), 30A(4,6 mm). Insulation material: PPO + PA.
Y Branch Solar Panel Connector Cable 30A 1 to2 Parallel Adapter Waterproof
Rated current: 20A(4mm²)30A(6mm²). Current : 20A~30A. Connector conductor material: Copper,Silver Plated. This Y Style MC 4 compatible Solar Cable Connector Set (Part # RX- MC 4Y-P) is a perfect solution to parallel connect multiple panels together.
5 Staubli Multi-Contact 32.0017P0001-UR MC4 Connector w/Boot Male PV-KST4/6II-UR
Lot of 5 – Staubli Multi-Contact 32.0017P0001-UR MC4 Connector w/Boot Male PV-KST4/6II-UR.
20Pcs Solar Cable Connectors 4mm-6mm 30Amp Waterproof Solar Panel Wire Joiners
Item SpecificsColor :BlackManufacturer Part Number :Does Not ApplyMaterial :Copper, Sliver platedColour :BlackBrand :UnbrandedType :Solar PanelUnit Type :UnitConnector Configuration :F, MConnector Type :Solar Panel ConnectorModel :MC4Rated Current :30AUnit Quantity :10 pair=20pcsCountry/Region of Manufacture :China Payment Pls know that we only accept payment from Paypal. Shipping Shipped item within 1 business day after payment cleared.Do not ship to PO Boxes, FPO and APO addresses.And we only ship to Paypal address. Pls make sure your Paypal address is your shipping address. Returns 30 days after received parcel gurantee. Contact Us If you have any problem before you place an order or receive parcel,pls contact us first.We will solve it for you.Thank you. All rights reserved. Shop Category Store Home Art Supplies Cell Phone Accessories Garden & Outdoor Living Health & Beauty Home Décor Home Improvement Household Supplies Kitchen Tools Labels & Tags & Stickers Lights & Lamps Party Supplies Workshop Tools OtherHot Item Indoor Outdoor Digital Thermometer Clock Temperature Meter Wireless Transmitter USD 12.96 Large Wind Chimes Bells Copper Tubes Outdoor Garden Home Hummingbird Butterfly USD 12.97 Propane Tank Gauge RV Pressure Brass Adapter Gas Level Meter Grill BBQ Indicator USD 12.37 6000PCS 10 Rolls Price Gun Tag Sticker Label Refill MX 5500 Paper White Red Line USD 8.75 5PCS Zipped Net Washing Bag Laundry Wash Bra Underwear Lingerie Clothes Socks USD 7.75 DeliveryNew List Item COB LED Magnetic Work Light Rechargeable Inspection Torch Lamp Flexible Cordless USD 8.74 USB Rechargeable LED Searchlight Portable Bright Handheld Spotlight Flashlight USD 11.85 6000Pa Cordless Handheld Vacuum Cleaner USB Rechargeable Car Auto Wet Dry Duster USD 19.83 360° IP 1080P E27 Light Bulb Security Camera WiFi IR Night Smart Home Wireless USD 19.99 2 Sizes Deep Resonance Serenity Metal Wind Chimes Bell Heroic Outdoor Windbell USD 8.32 Help & InfoPayment PolicyShipping PolicyReturn PolicyFAQAbout Us