3KW Wind Turbines 24V-48V Generator Windmill Energy Wind Power with Controller –

Patented permanent magnet ac generator with special stator, effectively reduce torque, well match the wind wheel and generator, and ensure the performance of whole system. Blades using new art of precision injection molding, matched with optimized aerodynamic shape and structure which enhance the wind energy utilization and annual output.

QuietKat 48V Portable E-bike Solar Charging Station

Carry the panel easily in the included bag, which fits nicely into any of the QuietKat Pannier Bags for easy transport. ONLY COMPATIBLE WITH QUIETKAT E-BIKE MODELS FROM 2020-2024 (EXCEPT APEX 1500W MODELS).

QuietKat 48V Portable E-bike Solar Charging Station

I bought the for my QuietKat e-bike, but haven’t used it. Carry the panel easily in the included bag, which fits nicely into any of the QuietKat Pannier Bags for easy transport. ONLY COMPATIBLE WITH QUIETKAT E-BIKE MODELS FROM 2020-2024 (EXCEPT APEX 1500W MODELS).

Enphase NEW IQ7 Micro Inverter IQ7-60-2-US & Q-Cable Brand New

The Enphase NEW IQ7 Micro Inverter IQ7-60-2-US is a brand new unit designed for grid-tie solar systems. With a maximum input power of 201-300 W and a maximum input voltage of 41-50 V, this microinverter offers overload protection and features corrosion-resistant design. The compact size of 1590 x 1053 mm and lightweight construction make it suitable for both indoor and outdoor environments. Featuring MPPT charging mode and a connector type of MC4, this Enphase IQ-7 model is a reliable option for home and garden energy management.

1000W Solar Grid Tie Inverter w/ Limiter MPPT Pure Sine Wave DC22-60V to 110VAC

Solar Grid Tie inverter MPPT Pure Sine Wave 1000W with Limiter DC22-60V New upgraded firmware Version 5.1 enable battery or solar limiter current and power model. User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of New upgraded firmware Version 5.1 enable battery or solar limiter current and power model. User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter . User can set kick in/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged . Introduction Why we produced the GTI-L — It is in response to the overwhelming clamor from our customers for a product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are reduced to insignificant levels, if not eliminated — because in some countries,the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if power is exported to the grid, thus, the consumers will be charged for power even if it is given to the grid, and this is the problem.This is the 2nd generation GTIL .The first generation GTIL must be used with an additional limiter module,we also add an switch button to enable the inverter either can work at limit mode or at normal grid tie mode. With the 2nd generation GTIL,we integrated the limit function inside the GTI-We call this internal limiter.In this way,No additional limiter module is needed,reduced customer’s cost,more easier for installation.But in case customer install inverter far away from the main circuit breaker,we also enable the 2nd GTIL work with stand-alone limiter,we call this-external limiter.For sure,the inverter can work under normal Grid tie-no limit mode,just set on the nice LCD and save your setting. Specifications: Input Data Input Voltage Range 22-65v Max input DC voltage 60V Peak power tracking voltage 25-60V Output Data Max output power 1000W Nominal Voltage 110vac/230vac auto sensing Nominal Voltage Range 95-140v Frequency Range 47.5-51.5 for 50hz; 59.3-60.5 for 60hz Power Factor >0.95 Output Waveform Pure sine wave Characteristic Data MPPT Efficiency 99% Over current protection yes Over temperature protection yes Reverse polarity protection yes Anti-island protection yes Stackable Just for AC output Operating temperature range -20 ‘C — +50 ‘C Inverter inside temperature -20 ‘C — +85 ‘C Current THD <5% Voltage THD 92% Warranty 2 years Settings Explainations on the LCD of the 2nd Generation GTIL: The GTIL including various functions,all functions should configurate on the LCD setting page.Please see below explaination: 1. Limit Mode:External limiter and Internal limiter are settable, Limit mode+External limiter both selected means work under external limiter mode. Limit mode+Internal limiter both selected means work under external limiter mode. 2.LCD back light:Select it,Lcd will always on.Unselect it,Lcd will auto turn off after about 10s without any action on lcd button.Press any of the button to light lcd again. 3.Remote Num:while using with wifi plug for monitoring,set by 1.While using with the WIFI-RTU(one rtu can monitoring multiple inverters),set monitored inverter numbers. 4.Bat or solar limited current mode:This function is usable while using with battery.the setted voltage will be the cut off voltage,this means while battery discharged to the setted voltage point or below setted point,inverter will auto disconnect from the battery and stop operating.This can prevent the battery from over discharged.The setted current means inverter will discharge the battery at this current level.Mppt function of the inverter will auto invalid when working under this setting.Set is 0.1V/step. 5.Reboot voltage:This setting voltage means while battery charged back,the inverter will auto restart after voltage reached the setting point.It convenient the user and make the function very flexible.Set is 0.1V/Step. 6.Battery and solar limited power mode:At this working mode,cut off voltage setting is same as 6.4,and the power setting is the maximum output power of the inverter.by this setting,user can limit the output power manually. Important information 7.1.The 22-65V type inverter will start up at 25V,and 45-90V type inverter will start up at 49.5V,after start,inverter can still work until 22v or 45v. 7.2.Current sensor Orientation:Please check the current flow direction arrow on the sensor before use,make sure the connection is correct.otherwise,inverter will not start up at limit mode. 7.3. Negative power under AC voltage means power overflow to the grid.positive means power come from the grid. Packing Iist: Inverter—1pcs; Clamp Sensor with 2m cable—1pcs; Power Cable—1pcs English Manual–1pcs; WARRANTY : 2Years Technical support and service are provided for the inverter the whole life. SHIPPING : We ship to international via EMS or FEDEX or DHL or TNT or other express . Items are shipped within 1-3 business day after receive cleared payment. FEEDBACK Note: Do not hesitate to talk with us anytime before and after the purchases, we are committed to your 100% customer satisfaction. I am here and ready to assist you with any question or concerns you might have before or after the purchase. If you have the problem with the power inverter, please talk with us first with eBay message BEOFRE you open return request or file a dispute or leave the netural or negative feedback. My goal is to make sure you are happy and having the pleasant shopping with us.

1000W Solar Grid Tie Inverter w/ Limiter MPPT Pure Sine Wave DC22-60V to 110VAC

Solar Grid Tie inverter MPPT Pure Sine Wave 1000W with Limiter DC22-60V New upgraded firmware Version 5.1 enable battery or solar limiter current and power model. User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of New upgraded firmware Version 5.1 enable battery or solar limiter current and power model. User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter . User can set kick in/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged . Introduction Why we produced the GTI-L — It is in response to the overwhelming clamor from our customers for a product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are reduced to insignificant levels, if not eliminated — because in some countries,the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if power is exported to the grid, thus, the consumers will be charged for power even if it is given to the grid, and this is the problem.This is the 2nd generation GTIL .The first generation GTIL must be used with an additional limiter module,we also add an switch button to enable the inverter either can work at limit mode or at normal grid tie mode. With the 2nd generation GTIL,we integrated the limit function inside the GTI-We call this internal limiter.In this way,No additional limiter module is needed,reduced customer’s cost,more easier for installation.But in case customer install inverter far away from the main circuit breaker,we also enable the 2nd GTIL work with stand-alone limiter,we call this-external limiter.For sure,the inverter can work under normal Grid tie-no limit mode,just set on the nice LCD and save your setting. Specifications: Input Data Input Voltage Range 22-65v Max input DC voltage 60V Peak power tracking voltage 25-60V Output Data Max output power 1000W Nominal Voltage 110vac/230vac auto sensing Nominal Voltage Range 95-140v Frequency Range 47.5-51.5 for 50hz; 59.3-60.5 for 60hz Power Factor >0.95 Output Waveform Pure sine wave Characteristic Data MPPT Efficiency 99% Over current protection yes Over temperature protection yes Reverse polarity protection yes Anti-island protection yes Stackable Just for AC output Operating temperature range -20 ‘C — +50 ‘C Inverter inside temperature -20 ‘C — +85 ‘C Current THD <5% Voltage THD 92% Warranty 2 years Settings Explainations on the LCD of the 2nd Generation GTIL: The GTIL including various functions,all functions should configurate on the LCD setting page.Please see below explaination: 1. Limit Mode:External limiter and Internal limiter are settable, Limit mode+External limiter both selected means work under external limiter mode. Limit mode+Internal limiter both selected means work under external limiter mode. 2.LCD back light:Select it,Lcd will always on.Unselect it,Lcd will auto turn off after about 10s without any action on lcd button.Press any of the button to light lcd again. 3.Remote Num:while using with wifi plug for monitoring,set by 1.While using with the WIFI-RTU(one rtu can monitoring multiple inverters),set monitored inverter numbers. 4.Bat or solar limited current mode:This function is usable while using with battery.the setted voltage will be the cut off voltage,this means while battery discharged to the setted voltage point or below setted point,inverter will auto disconnect from the battery and stop operating.This can prevent the battery from over discharged.The setted current means inverter will discharge the battery at this current level.Mppt function of the inverter will auto invalid when working under this setting.Set is 0.1V/step. 5.Reboot voltage:This setting voltage means while battery charged back,the inverter will auto restart after voltage reached the setting point.It convenient the user and make the function very flexible.Set is 0.1V/Step. 6.Battery and solar limited power mode:At this working mode,cut off voltage setting is same as 6.4,and the power setting is the maximum output power of the inverter.by this setting,user can limit the output power manually. Important information 7.1.The 22-65V type inverter will start up at 25V,and 45-90V type inverter will start up at 49.5V,after start,inverter can still work until 22v or 45v. 7.2.Current sensor Orientation:Please check the current flow direction arrow on the sensor before use,make sure the connection is correct.otherwise,inverter will not start up at limit mode. 7.3. Negative power under AC voltage means power overflow to the grid.positive means power come from the grid. Packing Iist: Inverter—1pcs; Clamp Sensor with 2m cable—1pcs; Power Cable—1pcs English Manual–1pcs; WARRANTY : 2Years Technical support and service are provided for the inverter the whole life. SHIPPING : We ship to international via EMS or FEDEX or DHL or TNT or other express . Items are shipped within 1-3 business day after receive cleared payment. FEEDBACK Note: Do not hesitate to talk with us anytime before and after the purchases, we are committed to your 100% customer satisfaction. I am here and ready to assist you with any question or concerns you might have before or after the purchase. If you have the problem with the power inverter, please talk with us first with eBay message BEOFRE you open return request or file a dispute or leave the netural or negative feedback. My goal is to make sure you are happy and having the pleasant shopping with us.